Remote Driving Control of a Mobile Vehicle using Electromyography (EMG) Signals Captured from Gesture-based Interactions
Article information
Abstract
Electromyography (EMG) signals are widely used in human-computer interaction (HCI) due to their high signal-to-noise ratio and ability to provide early information about muscle contractions. In this study, we present a mobile vehicle remotely controlled by EMG signals captured from hand-arm gestures. Specifically, we investigated gripping and wrist gestures. A single EMG sensor placed on the right forearm captured signals during gripping gestures with varying grip forces. Two EMG sensors placed on the left forearm recorded signals during wrist gestures with varying wrist folding angles. The EMG signals from the gripping gestures were evaluated based on grip force. The root mean square (RMS) value of these signals was used to control the driving speed and direction of the mobile vehicle. Similarly, the EMG signals from wrist gestures at different folding angles were characterized and used for differential speed control of the vehicle's driving wheels. A series of reliable demonstrations showcased the remote control of the mobile vehicle prototype using grip force and wrist gestures. Our approach is simple, effective, and reliable, achieving omnidirectional mobile vehicle control with both gesture-to-motion and sensor-to-motion ratios of 1.67, thereby contributing to appropriate technology for mobile and intelligent vehicles and related engineering and scientific applications, with a cost-effective design and simple configuration and operation.
Introduction
Over the past decades, there has been significant demand for human-computer interaction (HCI), which refers to digital interactions between humans and computers for specific operations (Bansal and Khan, 2018; Karray et al., 2008; Kawala-Janik et al., 2015; Ren and Bao, 2020). Bio-signals have been widely utilized in various engineering and scientific applications as convenient control tools for HCI (Kawala-Janik et al., 2015; Moon et al., 2005; Reaz et al., 2006), including medical diagnosis and monitoring (Reaz et al., 2006; Shustak et al., 2019; Suman et al., 2015), brain-computer interfaces (BCI) (Kawala-Janik et al., 2015; Nicolas-Alonso and Gomez-Gil, 2012; Palumbo et al., 2021), rehabilitation (Palumbo et al., 2021; Reaz et al., 2006), and more. Several types of bio-signals have been studied for these applications, such as electromyography (EMG), electrooculography (EOG), electroencephalography (EEG), and electrocardiography (ECG). Among these, EMG is often preferred for practical applications due to its relatively large amplitude and superior signal-to-noise ratio (SNR).
EMG is a myoelectric signal measured from the skin surface, generated by the electrical activity of muscle fibers during contractions (Konrad, 2006; Lucas et al., 2004; Moon et al., 2005; Osu and Gomi, 1999). When a muscle contracts to generate force, groups of muscle fibers known as motor units are innervated, activating motor unit action potentials (MUAPs) (Konrad, 2006). These simultaneously activated potentials in multiple muscle fibers are superimposed, forming the overall EMG signal. The EMG signal contains critical information about the timing, duration, and intensity of muscle activity during contractions (Lucas et al., 2004; Marras, 1990; Osu and Gomi, 1999). Consequently, EMG signals have been utilized in various applications, such as rehabilitation (Artemiadis, 2012; Lucas et al., 2004; Mulas et al., 2005), sports science (Oliver, 2014; Remaley et al., 2015; Sterzing et al., 2016), and medical research (Brauckhoff et al., 2016; Uribe et al., 2010). Among these, controlling a mobile vehicle via EMG signals has gained attention due to its fast response and intuitive control. However, most existing studies map a single gesture to a single motion, which increases the number of required gestures as the range of possible motions grows. Additionally, challenges remain in controlling a mobile vehicle solely using EMG sensors, without reliance on accelerometers or inertial measurement unit (IMU) sensors. To advance mobile vehicle applications, it is essential to develop systems capable of generating diverse motions with fewer gestures while enabling variable speed control.
This study presents a mobile vehicle remotely controlled by EMG signals captured during hand-arm gestures, specifically focusing on gripping and wrist gestures (extension and flexion). To effectively capture these signals, three surface EMG sensors were applied to the hand-arms. One EMG sensor, placed on the flexor carpi radialis (FCR) muscle of the right arm, recorded signals during the gripping gesture with varying grip forces. Two EMG sensors, positioned on the FCR and extensor carpi radialis (ECR) muscles of the left arm, measured signals during wrist extension and flexion gestures with varying wrist folding angles. The EMG signal for the gripping gesture was evaluated based on grip force, revealing that the root mean square (RMS) value of the signal over a specified time window (Tw) increased linearly with the grip force. This RMS value was utilized to control the vehicle's driving speed and direction (forward and backward). Similarly, the EMG signals recorded during wrist extension and flexion for different folding angles were characterized and applied for differential speed control of the vehicle's driving wheels. Reliable demonstrations showcased the prototype's ability to be controlled via gripping and wrist gestures. This proposed technique provides a cost-effective system with a simple configuration and simple operation. It can contribute to appropriate technology for mobile and intelligent vehicles, as well as rescue and logistics robots.
Participants
Two healthy adult male subjects participated in this study. Neither subject reported a history of upper-limb musculoskeletal or neuromuscular disorders. This study was approved by the Institutional Review Board of Kumoh National Institute of Technology, and written informed consent was obtained from both subjects prior to the experiments.
Methods
Figures 1(a-b) illustrate the speed and steering control mechanisms of the mobile vehicle proposed in this work. The EMG signals, generated by muscle activity during hand-arm gestures (specifically, gripping and wrist flexion/extension gestures), were acquired via the EMG sensors on the FCR muscle of the right arm and the ECR and FCR muscles of the left arm. As shown in Figure 1(a), the EMG sensor on the FCR muscle of the right arm captured the EMG signals during the gripping gesture with varying grip forces. The EMG sensors on the FCR and ECR muscles of the left arm captured the EMG signals during varying wrist extension and flexion angles, as shown in Figure 1(b). Although all forearm muscles (both flexors and extensors) are activated during the gripping gesture, the FCR muscle is known to be particularly sensitive (Larivière et al., 2010; Yao et al., 2022). The FCR muscle is responsible for wrist flexion, while the ECR muscle is responsible for wrist extension (Standring, 2016). These muscles were therefore chosen for the proposed gesture detection method. As shown in Figure 1(c), the EMG waveform acquired from the right FCR muscle during the gripping gesture effectively captures this motion. The RMS value (denoted by σ) of the waveform is calculated using Equation (1) for the specified time window Tw = nT, where T is the sampling period of the EMG waveform. In Equation (1), xk denotes the EMG waveform value at t = tk = kT. In this study, T = 0.05 ms and n = 2000, giving Tw = 100 ms. The resulting RMS values are plotted in Figure 1(d).
Schematic illustrations of (a) the speed and (b) the steering control mechanisms of the mobile vehicle. EMG waveforms and their corresponding RMS plots for (c-d) the right FCR muscle during a gripping gesture, (e-f) the left ECR muscle during a wrist extension gesture, and (g-h) the left FCR muscle during a wrist flexion gesture. (i) The EMG sensors placed on the right and left arms for the experiments. (j) Experimental setup consisting of a DAQ module and a custom-made communication interface. (k) Prototype of the mobile vehicle.
As shown in Figures 1(e-h), the waveforms captured on the ECR and FCR muscles of the left arm [Figure 1(e, g)] along with their RMS values [Figure 1(f, h)] effectively represent wrist extension and flexion motions. Figure 1(i) depicts the EMG sensors (MyoWare Muscle Sensor; Advancer Technologies) applied to each arm during the experiments. The speed of the mobile vehicle is controlled based on the grip force measured from the right FCR muscle. The differential speed of the vehicle's driving wheels is regulated according to the wrist folding angle, as measured from the ECR and FCR muscles of the left arm. Figure 1(j) shows the DAQ module (NI-USB6211; National Instruments) and a custom-made communication interface, which includes a microcontroller unit (Arduino Uno; Arduino) and a Bluetooth module (HC-42; Guangzhou Huicheng Information Technology Co., LTD), for acquiring EMG signals and transmitting the corresponding RMS values wirelessly to the mobile vehicle. The mobile vehicle prototype, presented in Figure 1(k), consists of a DC motor driver (DCMD-200-D; RINUC Inc.) and two DC motors with a maximum rotational speed of 150 rpm. It receives the RMS values of the EMG signals via the communication interface and controls the DC motor speed with pulse-width modulation (PWM).
Results and discussions
Speed control of mobile vehicle by gripping gesture
As shown in Figure 2(a), a handle equipped with load cells was prepared to characterize how the EMG signal varies with grip force. During the experiments, the handle was held vertically in a gripping posture, with the elbow positioned at an angle of approximately 135° between the upper arm and the forearm, while the forearm was aligned along the radial direction of the handle; see Figure 2(a). Grip force was measured using the load cells, and the EMG waveform was acquired from the right FCR muscle under varying grip forces. The RMS value of the waveform was then calculated using Equation (1). In this study, the RMS value of the EMG waveforms (s) was normalized with respect to the RMS value at the maximum grip force of 100 N (s100) and denoted as GNMA = s/s100. It represents the normalized muscle activity (NMA). The reference value of 100 N was determined from sustained maximal gripping, in which the subject maintained a firm grip for 1 min under the same posture shown in Figure 2(a). The average grip force during this period was approximately 100 N and was used as the normalization reference. Figures 2(b–g) show the NMA obtained over 5 seconds while gripping the handle under specified grip forces, ranging from 0 N to 100 N in 20 N increments. As the grip force increases, the overall level of the NMA signal becomes higher. In addition, the temporal variation of the signal becomes larger at higher grip forces, particularly in the 60–100 N conditions. This increased variation may be associated with the difficulty of maintaining a grip while exerting higher force levels.
Characterization of EMG signals with respect to grip force. (a) Experimental setup for measuring grip force and EMG signals. The grip force was measured using a gripping handle equipped with load cells. (b-g) RMS plots (NMA) of the EMG waveforms captured from the right FCR muscle under different applied grip forces: (b) 0 N (no grip force), (c) 20 N, (d) 40 N, (e) 60 N, (f) 80 N, and (g) 100 N.
Figure 3(a) plots the resulting NMA in terms of the grip force. As shown in Figure 3(a), the grip force and muscle activity exhibited a good linear relationship, expressed as GNMA = αFG + β (R2 = 0.9747), where FG represents the grip force. The fitting coefficients are α = 0.9516 and β = 6.238. The resulting NMA is sensitive and reliable with respect to the grip force across a broad range (0 N to 100 N). The operating ranges were mapped to regions where the NMA showed variations according to the grip force, as illustrated in Figure 3(a). Three stop bands were considered where the vehicle remains at rest (the speed of the DC motor, ω = 0). The corresponding stop bands are defined for GNMA < Glow, Gnorm – ε < GNMA < Gnorm + ε, and GNMA > Ghigh. The values used were Glow = 20%, Gnorm = 60%, ε = 10%, and Ghigh = 100%, respectively. In the region Glow < GNMA < Gnorm – ε, the speed of the DC motor was defined as ωL = ωR = ω = K(Gnorm – GNMA), where K is the gain, and ωL (ωR) represents the motor speed of the left (right) wheel of the vehicle. Since Gnorm > GNMA in this region, ω is positive, and the vehicle moves forward. In the region Gnorm + ε < GNMA < Ghigh, the speed of the DC motor defined as ωL = ωR = ω = K(Gnorm – GNMA) is negative, causing the vehicle to move backward. Figure 3(b) shows the vehicle moving forward, backward, and remaining at rest in the corresponding regions identified in Figure 3(a).
Steering control of mobile vehicle by wrist gesture
The NMA of the EMG waveforms captured from the sensors on the left ECR and FCR muscles at 0°, 45°, and 90° wrist extension and flexion angles are plotted in Figures 4(a-e). Each photo in Figures 4(a-e) shows the corresponding wrist position for the different extension and flexion angles. In Figure 4, the NMAs of the ECR and FCR muscles, denoted as ENMA and FNMA, respectively, were normalized by their RMS values obtained at 90° wrist extension (for ENMA) and 90° wrist flexion (for FNMA). Referring to Figures 4(b-c), ENMA was dominant during the wrist extension gesture, while FNMA was dominant during the wrist flexion gesture. Additionally, both ENMA and FNMA increased with larger wrist extension and flexion angles. As shown in Figure 5, when the wrist extension (flexion) angles were gradually increased from 0° to 90°, ENMA (FNMA) increased almost linearly. The ENMA and FNMA demonstrated well-defined and symmetric responses under the wrist extension and flexion gestures. Since ENMA (FNMA) was dominant during the wrist extension (flexion) gesture and its magnitude accurately represented the wrist extension (flexion) angle, ENMA and FNMA were used for the vehicle's steering control. The speeds of the DC motors driving the left and right wheels of the vehicle were controlled as ωL = ω + KLENMA and ωR = ω + KRFNMA. Here, ω = K(Gnorm – GNMA) is the speed determined by the gripping gesture, and KL and KR are the gains used to control the differential speed of the driving wheels based on the wrist gestures.
Characterization of EMG signals corresponding to various wrist angles. Photos of wrist gestures and the corresponding plots of NMA from the left ECR and FCR muscles at wrist folding angles of (a) 0° (neutral), (b) 45° extension, (c) 90° extension, (d) 45° flexion, and (e) 90° flexion.
NMA of the left ECR and FCR captured during gradual increases in the wrist (a) extension and (b) flexion angles.
Driving demonstration
We present a series of driving demonstrations for the vehicle prototype controlled by gripping gestures with GNMA, and wrist gestures with ENMA and FNMA. The operator was equipped with EMG sensors on the right FCR muscle, and the left ECR and FCR muscles. By varying the grip force while grasping a plastic handle with the right hand, the operator controlled the forward and backward driving speed of the vehicle (ω). The sensor on the FCR muscle of the operator’s right arm captured these variations as GNMA. Additionally, the operator adjusted the left wrist extension and flexion angles to steer the vehicle. The sensors on the ECR and FCR muscles of the operator’s left arm recorded the wrist extension and flexion angles as ENMA and FNMA, respectively.
A driving track (2,378 mm × 3,364 mm) printed on a paper was installed on the floor. The track consisted of two straight sections (home and back stretches) and two bends. The vehicle was remotely controlled to navigate the track with steering in counterclockwise (CCW) and clockwise (CW) directions. As shown in Figure 6(a-b), the vehicle, initially at rest, started from the home stretch, following the straightway to the right. A gripping gesture with the right hand was initiated to ensure Glow < GNMA < Gnorm – ε, while the wrist folding angle was zero. When the vehicle entered the first bend, it was controlled to turn left by extending the left wrist; see Figure 6(c). The extension of the left wrist was maintained for approximately 7 seconds, allowing the vehicle to follow the curvilinear path of the bend, as depicted in Figures 6(c-d). At the back stretch, the wrist position was reset, and GNMA from the gripping gesture drove the vehicle straight to the left [Figure 6(e)]. As the vehicle approached the second bend, the left wrist was extended again, enabling the vehicle to turn left back to the home stretch [Figures 6(f-h)]. Figure 6(i) plots GNMA, ENMA, and FNMA during the lap illustrated in Figures 6(a-h). The lap time was 32.8 seconds. Note that the grip force was maintained within the range Glow < GNMA < Gnorm – ε for the entire lap. Another lap was demonstrated in the opposite direction, as shown in Figures 7(a-h). Starting at rest, the vehicle initiated the movement by a gripping gesture to the left on the home stretch [Figure 7(a-b)]. The left wrist was flexed, causing the vehicle to turn right along the first bend [Figures 7(c-d)]. The vehicle continued straight along the back stretch and turned right along the second bend to return to the home stretch [Figures 7(e-h)]. GNMA, ENMA, and FNMA are plotted in Figure 7(i) for the lap shown in Figures 7(a-h). The lap time was 37.4 seconds. Throughout the lap, the grip force was kept within the range Glow < GNMA < Gnorm – ε. Supplementary Information (Movies S1 and S2) are provided for the driving demonstrations presented in Figures 6-7.
Counterclockwise (CCW) driving demonstration with the mobile vehicle. (a-h) Video snapshots of the mobile vehicle during the demonstration. (i) NMA profiles (GNMA, ENMA, and FNMA) measured over time during the driving demonstration.
Clockwise (CW) driving demonstration with the mobile vehicle. (a-h) Video snapshots of the mobile vehicle during the demonstration. (i) NMA profiles (GNMA, ENMA, and FNMA) measured over time during the driving demonstration.
Finally, a more complicated driving demonstration is presented along with Figure 8. In this demonstration, we designed the vehicle motion to include combinations of go forward/backward, turn right/left, and stop motions. Figures 8(a-h) illustrate the designed and demonstrated driving sequences: (a) The vehicle is initially at rest, (b) it goes forward, (c) turns right, (d) goes forward, (e) turns left, (f) goes forward, (g) stops at the marked parking position, (h) goes backward, and parks (stops) again at the final parking position. Figure 8(i) plots GNMA, ENMA, and FNMA during the driving demonstration shown in Figures 8(a-h). Supplementary Information (Movie S3) is provided for these driving demonstrations. As shown in Figures 6-8, the gripping gesture and the resulting GNMA reliably controlled the vehicle's forward and backward movements. The same signal was also effective for parking the vehicle at the desired position. Additionally, it was demonstrated that the vehicle was effectively and reliably steered using wrist gestures with extension and flexion angles (ENMA and FNMA).
Conclusion
In conclusions, we presented a remote driving control of a mobile vehicle via EMG signals captured by gripping and wrist gestures (extension and flexion). EMG signals under various grip force and wrist folding angles were characterized. We found that the NMAs of the FCR and ECR muscles of the hand-arms were sensitive and reliable to the grip force and wrist folding (extension and flexion) angles. The speed of the driving wheels of the mobile vehicle was controlled based on our findings. A series of remote driving control demonstrations was presented proving that the proposed technique was reliable and effective for the control of complicated motions of a mobile vehicle. Table 1 summarizes comparison between mobile vehicles using EMG signals with gesture-based interactions for their motion control. For the comparison, we introduced and used the values denoted by gesture-to-motion ratio and sensor-to-motion ratio. The gesture-to-motion ratio is defined as the number of distinct mobile robot motions generated per control gesture, while the sensor-to-motion ratio is defined as the number of distinct mobile robot motions generated per sensor. Higher values of both ratios indicate more efficient motion control, as omnidirectional mobile robot motion is achieved with fewer gestures and sensors. Referring to Table 1, this study achieves high gesture-to-motion and sensor-to-motion ratios (both 1.67), making our method relatively simple, intuitive, and cost-effective for motion control. While this study focused on demonstrating the feasibility of controlling a mobile vehicle using EMG signals generated by gripping and wrist gestures, further research is required to achieve more precise motion control. Future studies will include quantitative characterization of the driving wheel speeds and refinement of the control strategy based on the relationship between EMG signals and vehicle motion. This study provides a cost-effective approach with a simple configuration and simple operation, thus contributes to the appropriate technology and related applications, including mobile and intelligent vehicles, as well as rescue and logistics robots.
Supplementary Information
Supplementary movie S1.
Movie clip captures the driving demonstration in Figure 6.
Supplementary movie S2.
Movie clip captures the driving demonstration in Figure 7.
Supplementary movie S3.
Movie clip captures the driving demonstration in Figure 8.
Notes
Author contributions
G. -Y. L. conceptualized this work. G. -Y. L., K. -H. K., M. -H. L., S. -H. C. designed the experiments and set the experimental setups. K. -H. K., M. -H. L., S. -H. C., G. -M. M. conducted the experiments. G. -Y. L., K. -H. K., and M. -H. L., analyzed the data and wrote the paper, and all authors provided feedback. G. -Y. L. supervised the project.
Acknowledgements
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (RS-2024-00459127), the grant funded by Ministry of Trade, Industry and Energy (MOTIE, Korea) and the Korea Evaluation Institute of Industrial Technology (KEIT) (Grant No. 20017462), the Brain Korea 21 FOUR Project (Department of Aeronautics, Mechanical and Electronic Convergence Engineering, Kumoh National Institute of Technology), and the Gyeongsangbuk-do RISE (Regional Innovation System & Education) project (Specialized Industry Scale-up unit).
Conflicts of interest
The authors declare no conflict of interest.
Data Availability
All data generated and analyzed for this study are included in this manuscript.